Online UPS

> Products > Online UPS > PlusPRO 2 Series
LV Rack/Tower 1000VA to 3000VA

PlusPRO 2 Series
LV Rack/Tower 1000VA to 3000VA


The PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA is a true double conversion online UPS with pure sinewave output and zero transfer time in a rack and tower convertible unit. Featuring 1000VA, 3000VA configuration with wide AC input range, output power factor 0.9, LCD display, innovative Power Distribution Unit(PDU) and optional external battery bank, PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA model stand out as high efficient line of online UPS for mission critical equipment in data/computer center or industrial applications. 

* High performance true double conversion On Line UPS 1000VA to 3000VA
* Individual power distribution unit (PDU) maintenance bypass switch
* Intelligent Slot (SNMP) + USB multiple communications
* External battery bank to extend back-up time (Optional)
* Microprocessor control guarantees high reliability
* Low heat dissipation in long time operation
* Emergency power-off function (EPO)
* Automatic self-testing function
* High efficiency mode (ECO mode)  
* Output voltage regulation < 1%
* Power management software
* Output power factor 0.9
* Wide input range 
* DC start

MODEL PlusPRO 2-1000 PlusPRO 2-3000
CAPACITY 1KVA/0.9KW 3KVA/2.7KW
INPUT
Voltage 1 Phase 2 Wires with Ground 100/110/115/120Vac 
Voltage Range 55-150Vac 
Frequency  50Hz or 60Hz (Auto-Sensing)
THDi < 5% at full load
OUTPUT
Voltage  100/110/115/120Vac 
Voltage Regulation < 1%
Frequency ( Battery Mode) 50Hz or 60Hz +/- 0.1Hz 
Waveform Pure Sinewave
THD < 4%(linear load), < 8%(non-linear load) 
Crest Ratio 3 : 1
EFFICIENCY
To AC Mode > 89% at full load and battery full charged 
To Battery Mode > 85% at full load and battery full charged
To ECO Mode > 95% at full load and battery full charged
BATTERY
Voltage 36VDC 72VDC
Type 12V/7AH*3pcs 12V/9AH*6pcs 
Recharge Time 5 hours to 90% 5 hours to 90%
TRANSFER TIME
Line Mode to Battery Mode 0ms 
Inverter to Bypass, ECO Mode < 4ms
ECO Mode to Inverter < 10ms
DISPLAY
LCD Display

Input, Output, Load, Battery, Mode/Fault/Warning code, Inverter operating, Bypass operating,

Output voltage and frequency and Bypass disable/enable selection information

AUDIBLE ALARM
Battery Mode Beeps Every 4 Seconds
Low Battery Sounding Every  Second
Overload Sounding Twice Every  Second 
Fault Beeping continuously
COMMUNICATIONS
Interface (Port) USB Port
Intelligent Slot Slot for SNMP or AS400 card (Optional)
EPO Emergency Power Off
ENVIRONMENT
Operating Temperature 0-40℃
Humidity 20-90% (Non-condensing)
Acousitc Noise <45dB at 1M
PHYSICAL
Rack Height 2U 4U
Dimension (D*W*H) 480*440*90mm 480*440*180mm

PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA     Brochure     Download

PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA     English User Manual       Download

PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA       Chinese User Manual       Download