Line Interactive UPS

> Products > Line Interactive UPS > EML-E CH & EML-USB CH Series
600VA to 2000VA

EML-E CH & EML-USB CH Series
600VA to 2000VA


The EML-E CH & EML-USB CH Series 600VA to 2000VA provides guaranteed battery backup power during outage and unsafe fluctuation, along with full protection from damaging surges and spikes. Unique battery compartment makes it easy, fast and money saving to change battery. Featuring 600VA to 2000VA integrated with microprocessor controller, voltage stabilizer, LCD display and battery easy replacement in a stand-alone unit, EML-E CH & EML-USB CH Series UPS is the best choice to protect your data and keep you connected during utility blackout.
 

* Controlled by a technologically advanced microprocessor guaranteeing high reliability
* Equipped with 2-steps boost & 1-step buck AVR to stabilize output voltage
* Management software is designed to monitor and control UPS status (Optional)
* USB port and cable for managing functions via PC (Optional)
* Built-in DC start function enables UPS to be started without AC power supplied
* Constant current, constant voltage battery charger (CCCV Battery Charger)
* No-load shut down (UPS Green mode)
* UPS will charge itself even though power switch is off (Off mode charging)
* UPS will shut down upon battery low ; UPS will restart automatically upon AC recovery (Auto-restart)
* Over / under voltage protection (UPS will go to battery mode)
* Easy replacement battery design
* Lightning / surge protection 175 joules

MODEL EML-E 600CH EML-E 800CH EML-E 1000CH EML-E 1200CH EML-E 1500CH EML-E 2000CH
EML-USB 600CH EML-USB 800CH EML-USB 1000CH EML-USB 1200CH EML-USB 1500CH EML-USB 2000CH
CAPACITY 600VA/360W 800VA/480W 1000VA/600W 1200VA/720W 1500VA/900W 2000VA/1200W
INPUT
Voltage 110/115/120Vac or 220V/230/240Vac
Voltage Range  -30% +25%
Frequency  50Hz or 60Hz (Auto-Sensing)
OUTPUT
Voltage Regulation AC mode / Battery normal : 110/115/120Vac or 220/230/240Vac +/- 10%   
Frequency AC mode: 47-53Hz for 50Hz or 57-63Hz for 60Hz ; Battery mode:50Hz or 60Hz +/- 1Hz
Waveform Simulated Sinewave
Transfer Time < 6ms(Typical)

Outlet: Nema5-15R

or Universal Nema

4pcs backup/AVR + 4pcs surge only 5pcs backup/AVR + 5pcs surge only
Outlet: IEC-320 C13 4pcs backup/AVR + 4pcs surge only 8pcs backup/AVR + 4pcs surge only

Outlet: Australian/Schuko

/Universal/UK

2pcs backup/AVR + 4pcs surge only N/A

Outlet: IEC-320 C13*2pcs +

Australian/Schuko/Universal*4pcs

N/A 6pcs backup/AVR + 4pcs surge only

Outlet: IEC-320 C13*2pcs

+ UK*3pcs

N/A 5pcs backup/AVR + 4pcs surge only
BATTERY
Voltage 12VDC 24VDC
Type 12V/7AH*1pc 12V/9AH*1pc 12V/7AH*2pcs 12V/7AH*2pcs 12V/9AH*2pcs 12V/9AH*2pcs
Recharge Time 5 hours to 90% after complete discharge
Safety Protection Over Charge & Over Discharge Protection 

Advanced Battery

Management

Yes
DISPLAY
LCD Status Indicators Input voltage, Output voltage, Load level, Battery level, Fault, Battery fail, Overload, AC normal
AUDIBLE ALARM
Battery Mode Two short tones every 8 seconds
Low Battery Four short tones every second
Overload Beeping continuously
Fault Beeping continuously
MANAGEMENT
Smart USB Communication Port EML-E CH series: N/A
EML-USB CH series: Inlcuded, software support Windows 95/98/NT/2000/ME/XP/2003/Vista/7/8/10
ENVIRONMENT
Operating Temperature 0° C - 40° C (32℉~104℉)
Humidity 0-95% (Non-condensing)
Acousitc Noise <40 dB at 1M
PHYSICAL
Dimension (W*D*H) 315.5*100*141mm 343*135*208mm

EML-E CH & EML-USB CH Series 600VA to 2000VA        Brochure      Download

EML-E CH & EML-USB CH Series 600VA to 800VA          Manual         Download

EML-E CH & EML-USB CH Series 1000VA to 2000VA       Manual         Download