The PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA is a true double conversion online UPS with pure sinewave output and zero transfer time in a rack and tower convertible unit. Featuring 1000VA, 3000VA configuration with wide AC input range, output power factor 0.9, LCD display, innovative Power Distribution Unit(PDU) and optional external battery bank, PlusPRO 2 Series LV Rack/Tower 1000VA to 3000VA model stand out as high efficient line of online UPS for mission critical equipment in data/computer center or industrial applications.
#PlusPRO 2-1000 / PlusPRO 2-3000
* High performance true double conversion On Line UPS 1000VA to 3000VA
* Individual Power Distribution Unit (PDU) with maintenance bypass switch
* Intelligent Slot (SNMP) + USB multiple communications
* External battery bank to extend back-up time (Optional)
* Microprocessor control guarantees high reliability
* Low heat dissipation in long time operation
* Emergency power-off function (EPO)
* Automatic self-testing function
* High efficiency mode (ECO mode)
* Output voltage regulation < 1%
* Power management software
* Output power factor 0.9
* Wide input range
* DC start
MODEL | PlusPRO 2-1000 | PlusPRO 2-3000 | ||
CAPACITY | 1KVA/0.9KW | 3KVA/2.7KW | ||
INPUT | ||||
Voltage | 1 Phase 2 Wires with Ground 110/115/120Vac | |||
Voltage Range | 55-150Vac | |||
Frequency | 50Hz or 60Hz (Auto-Sensing) | |||
THDi | < 5% at full load | |||
OUTPUT | ||||
Voltage | 110/115/120Vac | |||
Voltage Regulation | < 1% | |||
Frequency ( Battery Mode) | 50Hz or 60Hz +/- 0.1Hz | |||
Waveform | Pure Sinewave | |||
THD | < 4%(linear load), < 8%(non-linear load) | |||
Crest Ratio | 3 : 1 | |||
EFFICIENCY | ||||
To AC Mode | > 89% at full load and battery full charged | |||
To Battery Mode | > 85% at full load and battery full charged | |||
To ECO Mode | > 95% at full load and battery full charged | |||
BATTERY | ||||
Type | Maintenance free sealed lead-acid battery | |||
Voltage | 36VDC | 72VDC | ||
Capacity & Number | 12V/7AH*3pcs | 12V/9AH*6pcs | ||
Recharge Time | 5 hours to 90% | 5 hours to 90% | ||
TRANSFER TIME | ||||
Line Mode to Battery Mode | 0ms | |||
Inverter to Bypass, ECO Mode | < 4ms | |||
ECO Mode to Inverter | < 10ms | |||
DISPLAY | ||||
LCD Display | Input, Output, Load, Battery, Mode/Fault/Warning code, Inverter operating, Bypass operating, Output voltage and frequency and Bypass disable/enable selection information | |||
AUDIBLE ALARM | ||||
Battery Mode | Beeps Every 4 Seconds | |||
Low Battery | Sounding Every Second | |||
Overload | Sounding Twice Every Second | |||
Fault | Beeping continuously | |||
COMMUNICATIONS | ||||
Interface (Port) | USB Port | |||
Intelligent Slot | Yes, but SNMP card is optional | |||
EPO | Emergency Power Off | |||
ENVIRONMENT | ||||
Operating Temperature | 0-40℃ | |||
Humidity | 20-90% (Non-condensing) | |||
Acousitc Noise | <45dB at 1M | |||
PHYSICAL | ||||
Rack Height | 2U | 4U | ||
Dimension (D*W*H) | 480*440*90mm | 480*440*180mm |
*Product specifications are subject to change without further notice.
*The capacity of connected loading do not exceed the capacity of UPS.